Marine RDYB-216 Intelligent Instrumentation

Brand: DEYUAN MARINE
Type: RDYB-216
voltage: DC18~DC28V
Accuracy: ±0.1%FS
Approval: CCS, DNV-GL, NK, BV, RINA, ABS
Input Signal: Pt100, 3-wire system
Overall Size: 80WX160HX140L(mm)
Cutout Size: 76WX153H(mm)
Availability:

Product Description

Marine RDYB-216 Intelligent Instrumentation


Product Introduction:

The RDYB-216 is a dedicated temperature monitoring and alarm instrument designed specifically for marine applications. It accepts temperature sensor inputs (PT100, thermocouple, or 4-20mA temperature transmitter) and provides clear local display with configurable alarm outputs. Ideal for engine rooms, cargo hold monitoring, refrigeration systems, and HVAC applications aboard all vessel types.


Main Technical Specification:

Working voltageDC18~DC28V
Measurement accuracy±0.1%FS
Input signalPt100, 3-wire system
Maximum measuring point16 point
Output relay capacityAC250V/2A
Relay outputsound and light alarm output
RS485 serial communication2400bps
Overall size80HX160WX140L(mm)
Cutout size76HX153W(mm)


Characteristic:

*Internal self-check and sensor fault judgment functions, strong anti-interference;


*With RS485 communication interface, it can be connected with PC;


*Can set the upper limit or lower limit of temperature alarm;


*Can be equipped with internal acoustic alarm,alarm indicator light and 2alarm relays with AC220V/2A capacity;


*If the temperature of any road is higher than the set alarm upper limit or lower than the alarm lower limit, the alarm indicator light of the corresponding road will light up, and the internal sound alarm will sound, and an alarm relay will be installed to act;


*The keyboard sets the slope and zero position to realize the calibration method without potentiometer, so that the measurement accuracy is not affected by mechanical vibration and the temperature drift is greatly reduced.


*Classification society approval;

Previous: 