SDS-RP Flush Type Repeater
Product Description
SDS-RP Flush Type Repeater
Product Introduction
Introducing our state-of-the-art Marine Flush Type Repeater, engineered to deliver critical navigation and instrumentation data with unparalleled reliability and seamless integration. Designed for flush mounting on bridge wings, chart rooms, engine control rooms, and other strategic locations, this repeater provides essential duplicated information from primary systems, ensuring constant situational awareness for the crew.
Constructed with a heavy-duty, marine-grade aluminum or stainless-steel bezel and a high-impact, optically clear glass face, our repeater is built to endure the harshest maritime environments. Its fully waterproof (IP67 or higher) and corrosion-resistant design guarantees long-term performance against saltwater, UV exposure, and extreme temperatures.
The unit offers exceptional clarity and readability through high-contrast digital displays, analog-style gauges, or a combination of both, featuring adjustable backlighting for optimal viewing in all conditions. It is compatible with all major international standard protocols (NMEA 0183/2000, IEC61162, etc.), allowing it to seamlessly repeat data from a wide range of primary sensors and displays—including compass headings (Gyro/GPS), rudder angle, propeller pitch/RPM, wind speed/direction, depth, and log speed.
Key benefits include enhanced operational safety by providing redundant data display at multiple control stations, facilitating efficient bridge resource management. Its sleek, low-profile, and flush-mounted design eliminates obtrusive protrusions, maximizing space and preventing accidental damage. Easy installation and configuration ensure a cost-effective solution for retrofitting existing vessels or integrating into new builds. Trust our Flush Type Repeater to be the reliable, high-fidelity link in your vessel's critical information chain.
Drawing
Technical Data
| Main power、Emergency power supply | AC220V±10%*3P,50/60HZ |
| Built-in battery | DC24V,4.5AH |
| Controller power consumption | Controller monitoring state:≤5W;alarm state:≤10W |
| Motor power consumption | 550W |
| Inspection cycle | ≤10 seconds(single point continuous patrolwhen the situation is abnormal) |
| Signal transmission distance between the repeater | ≤1500 meters |
| Working ambient temperature | 0℃~55℃ |
| Relative humidity | ≤95% |
Sample Extraction Smoke Detection System
Sample Extraction Smoke Detection System Connection Diagram