OMD-2005 15ppm Bilge Alarm 

OMD-2005 15ppm Bilge Alarm according to IMO Resolution MEPC.107 (49).

All monitors in our range are inspected and tested to the related I.M.O. requirements at   ou  r factories prior to delivery.
In normal use this 15ppm bilge alarm should operate correctly and without fault over a long period of   time requiring only small amounts of
maintenance to be carried out as outlined in the 
  instruction manuals.

 

Range (measurement & indication) 0 - 30 ppm, Trend up to 50ppm
Range (IMO specification) 0 - 15 ppm (according IMO regulations)
Accuracy better than IMO MEPC.107(49)
Electrical power supply 24V - 240V, AC or DC, automatic voltage adjustment
Electrical power consumption < 15 VA
Sample Oily water from separator outlet, 0,1 - 4 l/min
Sample temperature range +1°C  to +65°C
Sample connections R 1/4" Female
Alarm 1 & 2 Set Points 1 - 15ppm (independently adjustable)
Alarm 1 operating delay for annunciation 1 - 540 sec
Alarm 2 operating delay for control  1 - 10 sec
Alarm contacts 2 independently adjustable switchover contacts
Alarm contact operation mode De-energized in Alarm State
Alarm contact ratings 3A, 240V each
Alarm output 0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω
Display Green Graphic Display
Ambient temperature +1°C to +55°C
Class of protection IP 65
Dimensions 360 x 240 x 100 mm (WxHxD)
Weight 7,3 kgs